B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 44 of 52)
ADDR
REGISTER NAME
C65C
...Repeated for Contact Output 46
C668
...Repeated for Contact Output 47
C674
...Repeated for Contact Output 48
C680
...Repeated for Contact Output 49
C68C
...Repeated for Contact Output 50
B
C698
...Repeated for Contact Output 51
C6A4
...Repeated for Contact Output 52
C6B0
...Repeated for Contact Output 53
C6BC
...Repeated for Contact Output 54
C6C8
...Repeated for Contact Output 55
C6D4
...Repeated for Contact Output 56
C6E0
...Repeated for Contact Output 57
C6EC
...Repeated for Contact Output 58
C6F8
...Repeated for Contact Output 59
C704
...Repeated for Contact Output 60
C710
...Repeated for Contact Output 61
C71C
...Repeated for Contact Output 62
C728
...Repeated for Contact Output 63
C734
...Repeated for Contact Output 64
Reset (Read/Write Setting)
C750
FlexLogic™ operand which initiates a reset
Control Pushbuttons (Read/Write Setting) (7 modules)
C760
Control Pushbutton 1 Function
C761
Control Pushbutton 1 Events
C762
...Repeated for Control Pushbutton 2
C764
...Repeated for Control Pushbutton 3
C766
...Repeated for Control Pushbutton 4
C768
...Repeated for Control Pushbutton 5
C76A
...Repeated for Control Pushbutton 6
C76C
...Repeated for Control Pushbutton 7
Clear Records (Read/Write Setting)
C770
Clear Fault Reports operand
C772
Clear Event Records operand
C773
Clear Oscillography operand
C774
Clear Data Logger operand
C775
Clear Breaker 1 Arcing Current operand
C776
Clear Breaker 2 Arcing Current operand
C777
Clear Breaker 3 Arcing Current operand
C778
Clear Breaker 4 Arcing Current operand
C77C
Clear Channel Status operand
C77F
Clear Unauthorized Access operand
C782
Reserved (13 items)
Force Contact Inputs/Outputs (Read/Write Settings)
C7A0
Force Contact Input x State (96 items)
C800
Force Contact Output x State (64 items)
Channel Tests (Read/Write)
C840
Local Loopback Function
C841
Local Loopback Channel
C842
Remote Loopback Function
C843
Remote Loopback Channel
C844
Remote Diagnostics Transmit
Direct Input/Output Settings (Read/Write Setting)
C850
Direct Input Default States (8 items)
C858
Direct Input Default States (8 items)
B-52
RANGE
0 to 65535
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
---
0 to 2
0 to 3
0 to 1
1 to 2
0 to 1
1 to 2
0 to 2
0 to 1
0 to 1
L30 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F102
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
---
F001
---
1
F144
---
1
F131
---
1
F126
---
1
F001
---
1
F126
---
1
F001
---
1
F223
---
1
F108
---
1
F108
DEFAULT
0
0 (Disabled)
0 (Disabled)
0
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
0 (Disabled)
0 (No)
1
0 (No)
1
0 (NO TEST)
0 (Off)
0 (Off)
GE Multilin