GE L30 Instruction Manual page 453

Line current differential system, ur series
Hide thumbs Also See for L30:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 3 of 52)
ADDR
REGISTER NAME
User Displays Actuals (Read Only)
1080
Formatted user-definable displays (16 items)
Modbus User Map Actuals (Read Only)
1200
User Map Values (256 items)
Element Targets (Read Only)
14C0
Target Sequence
14C1
Number of Targets
Element Targets (Read/Write)
14C2
Target to Read
Element Targets (Read Only)
14C3
Target Message
Digital Input/Output States (Read Only)
1500
Contact Input States (6 items)
1508
Virtual Input States (8 items)
1510
Contact Output States (4 items)
1518
Contact Output Current States (4 items)
1520
Contact Output Voltage States (4 items)
1528
Virtual Output States (6 items)
1530
Contact Output Detectors (4 items)
Remote Input/Output States (Read Only)
1540
Remote Device States
1542
Remote Input States (4 items)
1550
Remote Devices Online
1551
Remote Double-Point Status Input 1 State
1552
Remote Double-Point Status Input 2 State
1553
Remote Double-Point Status Input 3 State
1554
Remote Double-Point Status Input 4 State
1555
Remote Double-Point Status Input 5 State
Direct Input/Output States (Read Only)
15A0
Direct Input 1-1 State (8 items)
15A8
Direct Input 1-2 State (8 items)
15B0
Direct Input 1 State
15B1
Direct Input 2 State
Ethernet Fibre Channel Status (Read/Write)
1610
Ethernet primary fibre channel status
1611
Ethernet secondary fibre channel status
Data Logger Actuals (Read Only)
1618
Data logger channel count
1619
Time of oldest available samples
161B
Time of newest available samples
161D
Data logger duration
Channel Status Commands (Read/Write Command)
1630
L90 Channel Status Clear
Channel Status Actuals (Read/Write Command)
1638
Channel 1 Asymmetry
1638
Channel 2 Asymmetry
Source Current (Read Only) (6 modules)
1800
Source 1 Phase A Current RMS
1802
Source 1 Phase B Current RMS
1804
Source 1 Phase C Current RMS
1806
Source 1 Neutral Current RMS
1808
Source 1 Phase A Current Magnitude
180A
Source 1 Phase A Current Angle
180B
Source 1 Phase B Current Magnitude
GE Multilin
RANGE
---
0 to 65535
0 to 65535
0 to 65535
0 to 65535
---
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 3
0 to 3
0 to 3
0 to 3
0 to 3
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 2
0 to 2
0 to 16
0 to 4294967295
0 to 4294967295
0 to 999.9
0 to 1
-65.535 to 65.535
-99.999 to 99.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
-359.9 to 0
0 to 999999.999
L30 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
---
F200
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
---
F200
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F126
---
1
F605
---
1
F605
---
1
F605
---
1
F605
---
1
F605
---
1
F108
---
1
F108
---
1
F500
---
1
F500
---
1
F134
---
1
F134
channel
1
F001
seconds
1
F050
seconds
1
F050
days
0.1
F001
---
1
F126
ms
0.001
F004
ms
0.001
F004
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
DEFAULT
(none)
0
B
0
0
0
"."
0
0
0
0
0
0
0
0
0
0 (No)
3 (Bad)
3 (Bad)
3 (Bad)
3 (Bad)
3 (Bad)
0 (Off)
0 (Off)
0
0
0 (Fail)
0 (Fail)
0
0
0
0
0 (No)
0
0
0
0
0
0
0
0
0
B-11

Advertisement

Table of Contents
loading

Table of Contents