B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 32 of 52)
ADDR
REGISTER NAME
9A0D
FlexElement™ 7 Actual
9A0F
FlexElement™ 8 Actual
VT Fuse Failure (Read/Write Setting) (6 modules)
A040
VT Fuse Failure Function
A041
...Repeated for module number 2
B
A042
...Repeated for module number 3
A043
...Repeated for module number 4
A044
...Repeated for module number 5
A045
...Repeated for module number 6
Selector switch actual values (read only)
A210
Selector switch 1 position
A211
Selector switch 2 position
Selector switch settings (read/write, 2 modules)
A280
Selector 1 Function
A281
Selector 1 Range
A282
Selector 1 Timeout
A283
Selector 1 Step Up
A284
Selector 1 Step Mode
A285
Selector 1 Acknowledge
A286
Selector 1 Bit0
A287
Selector 1 Bit1
A288
Selector 1 Bit2
A289
Selector 1 Bit Mode
A28A
Selector 1 Bit Acknowledge
A28B
Selector 1 Power Up Mode
A28C
Selector 1 Target
A28D
Selector 1 Events
A28E
Reserved (10 items)
A298
...Repeated for Selector 2
DNP/IEC Points (Read/Write Setting)
A300
DNP/IEC 60870-5-104 Binary Input Points (256 items)
A400
DNP/IEC 60870-5-104 Analog Input Points (256 items)
Flexcurves C and D (Read/Write Setting)
A600
FlexCurve C (120 items)
A680
FlexCurve D (120 items)
Non Volatile Latches (Read/Write Setting) (16 modules)
A700
Non-Volatile Latch 1 Function
A701
Non-Volatile Latch 1 Type
A702
Non-Volatile Latch 1 Set
A703
Non-Volatile Latch 1 Reset
A704
Non-Volatile Latch 1 Target
A705
Non-Volatile Latch 1 Events
A706
Reserved (4 items)
A70A
...Repeated for Non-Volatile Latch 2
A714
...Repeated for Non-Volatile Latch 3
A71E
...Repeated for Non-Volatile Latch 4
A728
...Repeated for Non-Volatile Latch 5
A732
...Repeated for Non-Volatile Latch 6
A73C
...Repeated for Non-Volatile Latch 7
A746
...Repeated for Non-Volatile Latch 8
A750
...Repeated for Non-Volatile Latch 9
A75A
...Repeated for Non-Volatile Latch 10
A764
...Repeated for Non-Volatile Latch 11
A76E
...Repeated for Non-Volatile Latch 12
B-40
RANGE
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
0 to 1
1 to 7
1 to 7
0 to 1
1 to 7
3 to 60
0 to 65535
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 65535
0 to 2
0 to 2
0 to 1
---
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 2
0 to 1
---
L30 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
0.001
F004
---
0.001
F004
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
0.1
F001
---
1
F300
---
1
F083
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F083
---
1
F300
---
1
F084
---
1
F109
---
1
F102
---
1
F001
---
1
F300
---
1
F300
ms
1
F011
ms
1
F011
---
1
F102
---
1
F519
0 (Reset Dominant)
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
---
F001
DEFAULT
0
0
0 (Disabled)
0
1
0 (Disabled)
7
50
0
0 (Time-out)
0
0
0
0
0 (Time-out)
0
0 (Restore)
0 (Self-reset)
0 (Disabled)
0
0
0
0
0
0 (Disabled)
0
0
0 (Self-reset)
0 (Disabled)
0