When No Power Distribution Units Are Installed - Fujitsu ETERNUS AF250 S2 Configuration Manual

All-flash arrays storage
Hide thumbs Also See for ETERNUS AF250 S2:
Table of Contents

Advertisement

Chapter 4
Connecting Cables
4.4
Power Cord Connection
The controller enclosure and drive enclosure have two power supply units (PSU#0 and PSU#1).
Make sure that the power cords are connected to all the power supply units.
4.4.1

When No Power Distribution Units Are Installed

The following procedure explains how to connect the power cords when no power distribution units are in-
stalled.
To help with power cord management and prevent incorrect connections, attach labels to the power cords
and make a note of connection origins and destinations.
1
Connect the power cord to the ETERNUS AF.
(1)
Connect the power cord plugs to the power inlets of the power supply units.
(2)
Fasten the plug of the power cord with the release tie.
Wrap the release tie around the power cord and fasten the release tie from either side. Make sure
that the release tie is not loose.
2
Connect the power cords to the socket.
Connect the plug at the other end of each power cord to the socket.
Connecting two power cords for each enclosure to different two power supply facilities improves the
availability of the power supply facilities against failures.
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
50
P3AG-1832-04ENZ0