Fujitsu ETERNUS AF250 S2 Configuration Manual page 112

All-flash arrays storage
Hide thumbs Also See for ETERNUS AF250 S2:
Table of Contents

Advertisement

Chapter 8
SAN Connection Settings
8.1
Connection Settings for the ETERNUS AF
8.1.2.2
iSCSI Port Parameter Settings
Set the connection information between the host interface port and the server.
The procedure to set the port parameters is as follows.
The setting screen that is displayed depends on the host interface port that is being used.
Set the connection information for the iSCSI ports on the ETERNUS AF and the server.
1
On the navigation of the ETERNUS Web GUI screen, click the [Connectivity] tab.
2
Select which iSCSI port to set the port parameters for and click [Configure iSCSI Port] in [Action].
The [Modify iSCSI Port Parameters] screen appears.
3
Select the target port, specify the items (for TCP/IP settings, iSCSI settings, basic settings, and security
settings), and then click the [Set] button.
iSCSI Name can be managed more easily if the port name is added to the end of the default.
When multiple target ports are selected, the parameters must be set for multiple ports.
Select the port to be set from the pull-down menu.
The following items are set as shown in this example.
Port
CM#0 CA#0 Port#0
IP Version
Select an IP address type. IPv4 is used in this example.
IP Address
Specify an available IP address for the iSCSI network that is to be connected.
For IPv4, the subnet mask needs to be specified.
iSCSI Name
For multipath connections, each name must be different.
CHAP
Specify [ON] to use unidirectional CHAP authentication or bidirectional CHAP authentication for the
target port and [OFF] to use neither of them.
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
112
P3AG-1832-04ENZ0