Chapter 10
System Status Check
10.6

Powering Off

10.6
Powering Off
To turn off the ETERNUS AF, perform one of the procedures below.
Via the power switch
Press the Power switch to turn off the ETERNUS AF.
Via ETERNUS Web GUI or ETERNUS CLI
Use ETERNUS Web GUI or ETERNUS CLI to turn off the ETERNUS AF.
The following methods can be used to turn off the power by linking with the server.
Via the power synchronized unit
Use the power synchronized unit to turn off the ETERNUS AF.
When turning off the ETERNUS AF, the power shuts off after the data in the cache memory is written to
the drives. As a result, it may take approximately eight minutes or up to 10 minutes maximum for the
power supply to be completely turned off.
Do not turn off the power of the ETERNUS AF and the network devices that connect the ETERNUS AF to a
server while the server is operating. This may result in the loss of data or prevent data from being saved
in the ETERNUS AF.
When using a power synchronized unit for power control, turn off the power of the ETERNUS AF via the
power synchronized unit. When a power synchronized unit is connected, the power of the ETERNUS AF is
automatically turned on because the power synchronization function is activated.
This section explains how to use the Power switch and the power synchronization unit to turn off the ETER-
NUS AF.
For other procedures, refer to the related manuals.
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED