I/O device 4 AO U/I 4×M12
Assignment in the process image output per device:
Figure E-11
IO-Link Master 4 IO-L + 8 DI + 4 DO DC 24V/1,3A 8×M12
During the STEP 7 configuration, you can select the address space according to use.
During GSD configuration, Slot 1 "4 IO-L" has fixed 32 bytes input and 32 bytes output.
Addressing of the input and output data can be selected freely using
Note
Value status (PortQualifier)
The value status (PortQualifier) is disabled by default. An active value status (PortQualifier)
is generally at byte x, bit 0 to bit 3. It can also be placed freely within the address space (byte
x to x+32).
Assignment of the inputs and IO-Link channels as an example:
Figure E-12
Address space of the IO-Link channels of the IO-Link Master 4 IO-L + 8 DI + 4 DO DC 24V/1,3A 8×M12
ET 200eco PN
Operating Instructions, 08/2016, A5E01250250-AJ
Address space of 4 AO U/I 4×M12 I/O device
I/O address space
S7-PCT
.
255