10
Main Menu Configuration Flowchart
10 MAIN MENU CONFIGURATION FLOWCHART
push
MENU
button
1) Once lockout security ID code is set "enable", the Menu will not be displayed through
Main Configuration Menu navigation.
2) To regain access to the locked Menu, user will be prompted for security ID code at
LCk.CNF Menu.
42
RUN
INPUt
RdG.CNF
INP.CNF
MP.SC.OF
OUt.CNF
SP.CNF
AL.CNF
Communication
Option Board
NO
Installed?
YES
COMM
COLOR
LCk.CNF
ENd
RUN
:Run mode
:INPUT selection Menu
:READING CONFIGURATION Menu
:INPUT CONFIGURATION Menu
:MULTI-POINT SCALE & OFFSET CONFIGURATION Menu
:OUTPUT CONFIGURATION Menu
:SETPOINT CONFIGURATION Menu
:ALARM CONFIGURATION Menu
:COMMUNICATION CONFIGURATION Menu
:LED COLOR SELECTION Menu
:LOCKOUT (ACCESS SECURITY) CONFIGURATION Menu
:End
:RUN mode