For ± 50V, 0-100V Ranges; Current/Process Value Input; For 0-20Ma Or 4-20Ma Range; Bridge Input - Omega DP41-B User Manual

Universal input meter
Hide thumbs Also See for DP41-B:
Table of Contents

Advertisement

6
Jumper Positions
6.3.4 For ± 50V, 0-100V ranges:
S1_K/A/B; SD2_G/H, jumpers are closed as shown:
S1

6.4 CURRENT/PROCESS VALUE Input:

6.4.1 For 0-20mA or 4-20mA range:

S1_K; S2_A/B/C/D, jumpers are closed as shown:
S1

6.5 BRIDGE Input:

6.5.1 For ± 50mV, 0-100mV ranges with Internal Excitation:
S1_L; S2_A/B/G/H, jumpers are closed as shown:
S1
6.5.2 For ±50mV, 0-100mV ranges with External Excitation:
S1_L; S2_A/B/H, jumpers are closed as shown:
S1
6.5.3 For ± 500mV, 1V ranges with Internal Excitation:
S1_L/E/F; S2_G/H, jumpers are closed as shown:
S1
6.5.4 For ± 500mV, 1V ranges with External Excitation:
S1_L/E/F; S2_H, jumpers are closed as shown:
S1