Communication Menu Configuration
AL.StAt
Press 'RESET/ENTER'
Press 'RESET/ENTER'
Press ' /MAX'
P.V.StAt
Press 'RESET/ENTER'
Press 'RESET/ENTER'
Press ' /MAX'
SNd.dAt
Press 'RESET/ENTER'
Press 'RESET/ENTER'
Press ' /MAX'
92
33) Display show "AL.StAt" Alarm Status Character setting submenu. If
necessary to select the other available following Bus Format submenus:
"P.V.StAt", "tyP.dAt", "FL.tRNS", "Pk.tRNS", "VL.tRNS", "SEPARA" and
"UNIt", use or press the 'MENU' button.
• For Universal meters, there is a list of the transmitted character (Hex
number value) corresponding for each of the sixteen (16) possible
Setpoint/Alarm (SP1, SP2, AL1/SP3 and AL2/SP4) states. Refer to
STATUS CHARACTER FORMATS/Alarm Status Characters Chapter of
Serial Communications Option Manual for detail description and
listing Table.
34) Display flashes "NO" No (Alarm Status Character excluded from Data
String as default) option or previous selection.
35) Scroll or select either "NO" to exclude or "yES" to include Alarm Status
Character in Data String Format for your choice of setting.
36) Display shows "StOREd" stored message momentarily and then
advances to the "P.V.StAt"
Peak & Valley Character Setting Submenu.
• The meter keeps track of Peak and Valley changes at the completion of
each measurement, so the occurrence of new values can be signaled.
However, transmissions of Peak/Valley status may be commanded less
often: therefore, the meter also monitors if Peak or Valley values have
changed since the last status transmission.
• These Characters only applies for Universal meters. Refer to STATUS
CHARACTER FORMATS/Peak & Valley (Hi/Lo) Status Characters
Chapter of Serial Communications option Manual for detail description
and listing Table.
37) Display flashes "NO" No (the Character Excluded as default) option or
previous selection.
38) Scroll and select either "NO" or "yES" to exclude or include the
character from Data String Format.
39) Display shows "StOREd" stored message momentarily and then
advances to the "SNd.dAt" Current Reading Value Transmission submenu
that allows user to select whether or not the data string transmitted is
included with current reading.
40) Display flashes, "yES" as included the current reading value in data
string as default or previous selection.
41) Scroll and select either "yES" to include or "NO" to exclude current
reading in data string transmitted.