Modbus Enter Modbus Protocol Submenu - Omega DP41-B User Manual

Universal input meter
Hide thumbs Also See for DP41-B:
Table of Contents

Advertisement

26
Communication Menu Configuration
SEPARA
Press 'RESET/ENTER'
Press 'RESET/ENTER'
Press ' /MAX'
UNIt
Press 'RESET/ENTER'
Press 'RESET/ENTER'
Press ' /MAX'
26.4. MOdbUS
Press 'RESET/ENTER'
Press 'RESET/ENTER'
Press ' /MAX'
94
51) Display shows "StOREd" stored message momentarily and then
advances to the "SEPARA" Separator Selection submenu that determines
whether different data types included in Data String and sent from the
device will be separated by spaces or by Carriage Returns.
52) Display flashes "SPACE" Space separator as default or previous
selection.
53) Scroll and select "SPACE" or "CR" <CR> Carriage Return Option for
your choice of Data String Format.
54) Display shows "StOREd" stored message momentarily and then
advances to the "UNIt" Unit of Measure submenu that allows user to
include user-Defined unit of measurement in Data String Format (For detail
and description of how to create your own units of measurement, refer to
Serial Communication Operation Manual).
55) Display flashes "NO" No (excluded as default) option or previous
selection.
56) Scroll and select "NO" to exclude or "yES" to include your own defined
unit of measure in the Data String for your choice of Data Format.
Enter MODBUS PROTOCOL SUBMENU
57) Display shows "StOREd" stored message momentarily and then
advances to the "MOdbUS" Modbus Protocol submenu.
58) Display flashes "NO" No option as default as Modbus Protocol
disabled or previous selection.
59) Scroll and select "NO" to disable or "yES" to enable Modbus protocol.
If Modbus Protocol was selected, the following Communications
Parameters must be set as: No Parity, 8-bit Data Bit, 1-Stop Bit.
Do not attempt to change these parameters.