Chapter 7. Wiring Test On Fiber-Optic Conductors And Sfp Modules; Safety Precautions; Instructions For Cleaning Sfp Modules And Patch Cables - IDEAL Networks LanXPLORER Pro Manual

Gigabit ethernet network analyzer
Hide thumbs Also See for LanXPLORER Pro:
Table of Contents

Advertisement

Chapter 7.
modules
7.1
ATTENTION!
Never look directly into the socket of the SFP module, at connector surfaces, open fiber ends or
into connectors. The danger exists that light in the non-visible spectrum could be emitted and
permanently damage your eyes.
If you are not sure whether the device is switched on or if the fiber is conducting light, always be
on the safe side and assume that light could be emitted.
Treat open fibers properly; fiber splinters can pose an injury hazard.
Protect your eyes when working on open fibers; fiber splinters can cause permanent eye damage.
Never leave fiber remnants lying around open and never dispose of such remnants loose with
domestic wastes; the fiber splinters pose an injury hazard.
Before cleaning SFP modules, we recommend removing them from the instrument. This ensures
that light cannot be admitted inadvertently during the cleaning process.
CAUTION!
Observe the maximum measuring range when connecting SFP modules to a light conducting link
(see specifications for individual SFP modules). Exceeding this distance can lead to damage to the
SFP modules.
7.2
NOTE:
Before connecting the measuring cables to the SFP modules, ensure that the connectors on the
measuring cables are clean.
Clean the ferrule on the SFP sockets with dry, lint-free, non-scratching materials.
The connectors can be cleaned with suitable fiber-glass cleaning cloths or cleaning swabs. IDEAL
recommends cleaning set #1219-00-1621 for care of the SFP modules and patch cables.
LanXPLORER Pro
User Manual
Wiring test on fiber-optic conductors and SFP

Safety precautions

Instructions for cleaning SFP modules and patch cables

150835 Iss 5
Page 52

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents