Advanced Parameters

This is a quick reference to all parameters in the drive showing units,
ranges, limits etc, with block diagrams to illustrate their function. Full
parameter descriptions can be found in the Advanced User Guide on the
supplied CD ROM.
These advanced parameters are listed for reference purposes only. The
lists in this chapter do not include sufficient information for adjusting
these parameters. Incorrect adjustment can affect the safety of the
system, and damage the drive and or external equipment. Before
attempting to adjust any of these parameters, refer to the Advanced
User Guide.

Table 11-1 Menu descriptions

Menu
1
Speed reference selection, limits and filters
2
3
Speed feedback and speed control
4
Torque and current control
5
6
7
8
9
Programmable logic and motorized pot
10
Drive status and trip information
11
Threshold detectors, variable selectors and brake
12
13
14
15
Slot 1 Solutions Module menu
16
Slot 2 Solutions Module menu
17
Slot 3 Solutions Module menu
18
User application menu 1 (saved in drive EEPROM)
19
User application menu 2 (saved in drive EEPROM)
20
User application menu 3 (not saved in drive EEPROM)
21
Second motor parameters
22
Additional Menu 0 set up
23
Default abbreviations:
EUR> European default value
USA> USA default value
NOTE
Parameter numbers shown in brackets {...} are the equivalent sub block/
Menu 0 parameters.
In some cases, the function or range of a parameter is affected by the
setting of another parameter; the information in the lists relates to the
default condition of such parameters.
90
Electrical
Getting
Basic
Installation
Started
parameters
Function
Ramps
Motor and field control
Sequencer and clock
Analog I/O
Digital I/O
General drive set-up
control function
Position control
User PID controller
Header selections
Running the
SMARTCARD
Optimization
Motor
Operation
Coding
The coding defines the attributes of the parameter as follows.

Table 11-2 Key to parameter table coding

Coding
{X.XX}
Copied Menu 0 or advanced parameter
Bit
1 bit parameter: 'On' or 'OFF' on the display
Bi
Bipolar parameter
Uni
Unipolar parameter
Txt
Text: the parameter uses text strings instead of numbers.
SP
Spare: not used
Filtered: some parameters which can have rapidly changing
FI
values are filtered when displayed on the drive keypad for
easy viewing.
Destination: This parameter selects the destination of an
DE
input or logic function.
Variable maximum: the maximum of this parameter can
VM
vary.
Decimal place: indicates the number of decimal places used
DP
by this parameter.
No default: when defaults are loaded (except when the drive
ND
is manufactured or on EEPROM failure) this parameter is
not modified.
Rating dependent: this parameter is likely to have different
values and ranges with drives of different voltage and
current ratings. Parameters with this attribute will not be
transferred to the destination drive by SMARTCARDs when
RA
the rating of the destination drive is different from the source
drive and the file is a parameter file. However, the value will
be transferred if only the current rating is different and the
file is a differences from default type file.
Not copied: not transferred to or from SMARTCARDs during
NC
copying.
NV
Not visible: not visible on the keypad.
PT
Protected: cannot be used as a destination.
User save: parameter saved in drive EEPROM when the
US
user initiates a parameter save.
RW
Read/write: can be written by the user.
RO
Read only: can only be read by the user.
Bit default one/unsigned: Bit parameters with this flag set to
one have a default of one (all other bit parameters have a
BU
default of zero. Non-bit parameters are unipolar if this flag is
one.
Power-down save: parameter automatically saved in drive
EEPROM when the under volts (UV) trip occurs. Power-
PS
down save parameters are also saved in the drive when the
user initiates a parameter save.
www.emersonct.com
Onboard
Advanced
Technical
Diagnostics
PLC
Parameters
Data
Attribute
Quantum MP User Guide
UL
Information
Issue: A4