Figure 10-2 Programming options for Quantum MP
Level 1
Onboard PLC with SYPTLite software
10.4
Getting started
SYPTLite can be found on the CD which is supplied with the drive.
SYPTLite system requirements
•
Windows 2000/XP/Vista. Windows 95/98/98SE/Me/NT4 are not
supported
•
Pentium III 500 MHz or better recommended
•
128MB RAM
•
Minimum of 800x600 screen resolution. 1024x768 is recommended
•
Adobe Acrobat 5.10 or later (for viewing User Guides)
•
Microsoft Internet Explorer V5.0 or later
•
RS232 to RS485, RJ45 communications lead to connect the PC to
the drive
•
Administrator rights are required to install the software
To install SYPTLite, insert the CD and the auto-run facility should start
up the front-end screen, from which SYPTLite can be selected.
See the SYPTLite help file for more information regarding using
SYPTLite, creating ladder diagrams and the available function blocks.
88
Electrical
Getting
Basic
Running the
Installation
Started
parameters
Level 2
SM-Applications Lite V2 with
SYPTLite software
SMARTCARD
Optimization
Motor
Operation
Level 3
SM-Applications Lite V2
with SYPT software
10.5
Onboard PLC parameters
The following parameters are associated with the Onboard PLC
program.
11.47
Drive Onboard PLC program enable
RW
Uni
0 to 2
This parameter is used to start and stop the drive Onboard PLC program.
Value
0
Halt the drive Onboard PLC program.
Run the drive Onboard PLC program (if installed). Any out-of-
range parameter writes attempted will be clipped to the
1
maximum / minimum values valid for that parameter before
being written.
Run the drive Onboard PLC program (if installed). Any out-of-
2
range parameter writes attempted will cause a 'UP ovr' trip.