Emerson Quantum MP User Manual page 102

High performance dc drive size 1 and size 2 45a to 700a, 480v two or four quadrant operation
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Parameter
2.01
Post ramp reference
2.02
Ramp enable
2.03
Ramp hold
2.05
Ramp output selector
2.06
S ramp enable
2.07
S ramp acceleration limit
2.10
Acceleration rate selector
2.11
Acceleration rate 1
2.12
Acceleration rate 2
2.13
Acceleration rate 3
2.14
Acceleration rate 4
2.15
Acceleration rate 5
2.16
Acceleration rate 6
2.17
Acceleration rate 7
2.18
Acceleration rate 8
2.19
Jog acceleration rate
2.20
Deceleration rate selector
2.21
Deceleration rate 1
2.22
Deceleration rate 2
2.23
Deceleration rate 3
2.24
Deceleration rate 4
2.25
Deceleration rate 5
2.26
Deceleration rate 6
2.27
Deceleration rate 7
2.28
Deceleration rate 8
2.29
Jog deceleration rate
2.30
Actual ramp rate selected
2.31
Actual ramp rate selected
2.32
Acceleration select bit 0
2.33
Acceleration select bit 1
2.34
Acceleration select bit 2
2.35
Deceleration select bit 0
2.36
Deceleration select bit 1
2.37
Deceleration select bit 2
Inertia compensation
2.38
torque
2.39
Ramp rate speed units
2.40
Time of S ramp
2.41
S ramp mode
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
102
Electrical
Getting
Basic
Installation
Started
parameters
Range(
{di03, 0.38}
±SPEED_MAX rpm
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0 to 100.000 s
{SE03, 0.24} 0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
{SE04, 0.25} 0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
0 to MAX_RAMP_RATE s / (Pr 1.06 OR Pr 2.39)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
± 1,000.0%
0 to 10000rpm
0 to 100.000s
OFF (0) or On (1)
Uni
Unipolar
Bi
NC
Not copied
RA
Running the
SMARTCARD
Optimization
Motor
Operation
)
2
/1000rpm
0 to 9
0 to 9
1 to 8
1 to 8
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
www.emersonct.com
Onboard
Advanced
Technical
Diagnostics
PLC
Parameters
Data
Default(
)
RO
On (1)
RW Bit
0
RW Bit
On (1)
RW Bit
0 Eur: 0, USA: 1
RW Bit
3.600
RW Uni
0
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
0
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
5.000
RW Uni
10.000
RW Uni
RO Uni
RO Uni
RW Bit
RW Bit
RW Bit
RW Bit
RW Bit
RW Bit
RO
0
RW Uni
1.250
RW Uni
On (1)
RW Bit
Txt
Text string
US
User save
PS
Quantum MP User Guide
UL
Information
Type
Bi
NC PT
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
NC PT
NC PT
NC
NC
NC
NC
NC
NC
Bi
NC PT
US
US
US
Power down save
Issue: A4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents