Model Number - Emerson Quantum MP User Manual

High performance dc drive size 1 and size 2 45a to 700a, 480v two or four quadrant operation
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
2.2.1
Typical short-term overload limits
The maximum percentage overload limit changes depending on the
selected motor
Variations in motor rated current will result in changes in the maximum
possible overload as detailed in the Advanced User Guide.
Figure 2-1 can be used to determine the maximum overload duration
available for overloads between 100% and 150%. For example the
maximum overload available for a period of 60 seconds is 124%.
Figure 2-1 Maximum overload duration available
160
155
150
145
overload
(%)
140
135
130
125
120
115
110
105
100
NOTE
Overload of 150% for 30s is available with ambient temperature of 40C
(104°F) up to a maximum of 10 repetitions per hour.
2.3

Model number

The way in which the model numbers for the Quantum MP range are formed is described in Figure 2-2.
Figure 2-2 Model number
Quantum product line
QMP: Quantum Platform
Continuous armature current rating (A)
Voltage rating
4: 480V
R
- 4 quadrant operation
Blank
- 2 quadrant operation
Quantum MP User Guide
Issue: A4
Electrical
Getting
Basic
Installation
Started
parameters
overload duration (seconds)
QMP 2 1 0 A
www.emersonct.com
Running the
SMARTCARD
Optimization
Motor
Operation
4
R
Onboard
Advanced
Technical
Diagnostics
PLC
Parameters
Data
UL
Information
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents