Safety
Product
Mechanical
Information
Information
Installation
2.2.1
Typical short-term overload limits
The maximum percentage overload limit changes depending on the
selected motor
Variations in motor rated current will result in changes in the maximum
possible overload as detailed in the Advanced User Guide.
Figure 2-1 can be used to determine the maximum overload duration
available for overloads between 100% and 150%. For example the
maximum overload available for a period of 60 seconds is 124%.
Figure 2-1 Maximum overload duration available
160
155
150
145
overload
(%)
140
135
130
125
120
115
110
105
100
NOTE
Overload of 150% for 30s is available with ambient temperature of 40C
(104°F) up to a maximum of 10 repetitions per hour.