Table 4-25 Control Connection Recommended Cable Sizes - Emerson Quantum MP User Manual

High performance dc drive size 1 and size 2 45a to 700a, 480v two or four quadrant operation
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Source
Indicates the parameter being output by the terminal
parameter:
Mode
Analog - indicates the mode of operation of the terminal,
parameter:
i.e. voltage 0-10V, current 4-20 mA etc.
Digital - indicates the mode of operation of the terminal,
i.e. positive / negative logic, open collector.
All analog terminal functions can be programmed in menu 7.
All digital terminal functions (including the relays) can be programmed in
menu 8.
The setting of Pr 6.04 can cause the function of digital inputs T25 to T27
to change. For more information, refer to section on page 144.
If the control circuits are to be connected to other circuits
classified as Safety Extra Low Voltage (SELV) (e.g. to a
personal computer), an additional isolating barrier must be
included in order to maintain the SELV classification.
WARNING
If any of the digital inputs (including the drive enable input)
are connected in parallel with an inductive load (i.e.
contactor or motor brake) then suitable suppression (i.e.
diode or varistor) should be used on the coil of the load. If no
CAUTION
suppression is used then over voltage spikes can cause
damage to the digital inputs on the drive.
The control circuits are isolated from the power circuits in the
drive by basic insulation (single insulation) only. The installer
must ensure that the external control circuits are insulated
from human contact by at least one layer of insulation
WARNING
(supplementary insulation) rated for use at the AC supply
voltage.
Status relay contacts are over-voltage category II.
WARNING
A fuse or other over-current protection should be installed to
the relay circuit.
WARNING

Table 4-25 Control connection recommended cable sizes

Terminal
Minimum cable size
Machine armature
Auxiliary
Control I/O - 24V
Encoder
Tachgenerator
0.5mm
Status relays
120V I/O control
Size 1
120V I/O control
Size 2
Quantum MP User Guide
Issue: A4
Electrical
Getting
Basic
Installation
Started
parameters
Maximum cable size
2
5mm
10 AWG
2
1.31mm
16 AWG
2
20 AWG
2
2.5mm
12 AWG
2
2.08mm
14 AWG
www.emersonct.com