Emerson Quantum MP User Manual page 107

High performance dc drive size 1 and size 2 45a to 700a, 480v two or four quadrant operation
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Parameter
4.01
Current magnitude
4.02
Filtered current magnitude
4.03
Torque demand
4.04
Current demand
4.05
Motoring current limit
4.06
Regen current limit
4.07
Symmetrical current limit
4.08
Torque reference
4.09
Torque offset
4.10
Torque offset select
4.11
Torque mode selector
4.12
Current demand filter 1
4.13
Continuous current controller Kp gain
4.14
Continuous current controller Ki gain
4.15
Thermal time constant
4.16
Thermal protection mode
4.18
Overriding current limit
4.19
Overload accumulator
4.20
Percentage load
4.22
Inertia compensation enable
4.23
Current demand filter 2
4.24
User current maximum scaling
4.27
Current taper 1 threshold
4.28
Current taper 2 threshold
4.29
Current taper 1 end point
4.30
Current taper 2 end point
4.31
Taper threshold 1 exceeded
4.32
Taper threshold 2 exceeded
4.33
Slew rate limit
4.34
Discontinuous current controller Ki gain
4.35
Extra safe bridge change
Reduced hysteresis for bridge change
4.36
over
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
Quantum MP User Guide
Issue: A4
Electrical
Getting
Basic
Installation
Started
parameters
Range(
{di08, 0.43}
0 to DRIVE_CURRENT_MAX A
0 to DRIVE_CURRENT_MAX A
{di07, 0.42}
±TORQUE_PROD_CURRENT_MAX %
±TORQUE_PROD_CURRENT_MAX %
0 to MOTOR1_CURRENT_LIMIT_MAX %
0 to MOTOR1_CURRENT_LIMIT_MAX %
0 to MOTOR1_CURRENT_LIMIT_MAX %
±USER_CURRENT_MAX %
±USER_CURRENT_MAX %
OFF (0) or On (1)
0 to 4
0 to 25.0 ms
0 to 4,000
0 to 4,000
0 to 3000.0
0 to 1
0 to TORQUE_PROD_CURRENT_MAX %
0 to 100.0 %
±USER_CURRENT_MAX %
OFF (0) or On (1)
0.0 to 25.0 ms
0.0 to TORQUE_PROD_CURRENT_MAX %
0 to 10,000.0 rpm
0 to 10,000.0 rpm
0 to 1,000.0%
0 to 1,000.0%
OFF (0) or On (1)
OFF (0) or On (1)
0.0 to 60,000%s
0 to 4,000
OFF (0) or On (1)
OFF (0) or On (1)
Uni
Unipolar
Bi
NC
Not copied
RA
www.emersonct.com
Running the
SMARTCARD
Optimization
Motor
Operation
)
-1
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Onboard
Advanced
Technical
Diagnostics
PLC
Parameters
Data
Default(
)
RO Uni FI NC PT
RO Uni FI NC PT
RO
RO
150.0
RW Uni
150.0
RW Uni
150.0
RW Uni
0.0
RW Bi
0.0
RW Bi
OFF (0)
RW Bit
0
RW Uni
0.0
RW Uni
100
RW Uni
50
RW Uni
89.0
RW Uni
0
RW Bit
RO Uni
RO Uni
RO
OFF (0)
RW Bit
0.0
RW Uni
150.0
RW Uni
10,000.0 rpm
RW Uni
10,000.0 rpm
RW Uni
1,000.0%
RW Uni
1,000.0%
RW Uni
RO Bit
RO Bit
7,000
RW Uni
200
RW Uni
OFF (0)
RW Bit
OFF (0)
RW Bit
Txt
Text string
US
User save
PS
UL
Information
Type
Bi
FI NC PT
Bi
FI NC PT
RA
US
RA
US
RA
US
US
US
US
US
US
US
US
US
US
NC PT
NC PT
Bi
FI NC PT
US
US
RA
US
US
US
US
US
US
US
US
US
Power down save
107

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents