Emerson Quantum MP User Manual page 162

High performance dc drive size 1 and size 2 45a to 700a, 480v two or four quadrant operation
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Trip
S.OV
Excessive suppressor voltage
Operation of the drive requires the installation of the external suppressor resistance, see section 4.10 External suppressor
172
resistor on page 42.
t002
Reserved
A value of 2 is being written to user trip (Pr 10.38). The drives internal logic, on board or Solutions Module program must be
2
interrogated. The program should be modified so that only trips defined as User trip are used.
t004
Reserved
4
See diagnosis for t002
t010
Reserved
10
See diagnosis for t002
t019
Reserved
19
See diagnosis for t002
t023
User trip
This trip is user defined. The drives internal logic, on board or Solutions module program must be interrogated to find the cause of
23
this trip. A value of 23 is being written to user trip (Pr 10.38)
t032
Reserved
32
See diagnosis for t002
t033
Reserved
33
See diagnosis for t002
t038 to t039
Reserved
33
See diagnosis for t002
t040 to t089
User trip
40 to 89
See diagnosis for t023
t099
User trip defined in 2
99
This solutions module program must be interrogated to find the cause of this trip. A value of 99 is being written to user trip (Pr 10.38)
t101
User trip
101
See diagnosis for t023
t102 to t111
Reserved
102 to 111
See diagnosis for t002
t112 to t156
User trip
112 to 156
See diagnosis for t023
t161 to t167
Reserved
161 to 167
See diagnosis for t002
t176
Reserved
176
See diagnosis for t002
t192
Reserved
192
See diagnosis for t002
t194 to tl196
Reserved
194 to 196
See diagnosis for t002
t216
User trip
216
See diagnosis for t023
th
Motor thermistor trip
Check motor temperature
24
Check thermistor continuity
Set Pr 7.15 (in01, 0.81) = VOLt and reset the drive to disable this function
th.Err
Missing SCR
173
Hardware fault - return drive to supplier
162
Electrical
Getting
Basic
Installation
Started
parameters
nd
processor Solutions Module code
Running
SMARTCARD
Optimization
the Motor
Operation
Diagnosis
www.emersonct.com
Onboard
Advanced
Technical
Diagnostics
PLC
Parameters
Data
Quantum MP User Guide
UL
Information