Emerson Quantum MP User Manual page 158

High performance dc drive size 1 and size 2 45a to 700a, 480v two or four quadrant operation
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Trip
C.cPr
SMARTCARD trip: The values stored in the drive and the values in the data block on the SMARTCARD are different
188
Press the red
C.dAt
SMARTCARD trip: Data location specified does not contain any data
183
Ensure data block number is correct
C.Err
SMARTCARD trip: SMARTCARD data is corrupted
Ensure the card is located correctly
182
Erase data and retry
Replace SMARTCARD
C.Full
SMARTCARD trip: SMARTCARD full
184
Delete a data block or use different SMARTCARD
cL2
Analog input 2 current loss (current mode)
28
Check analog input 2 (terminal 7) current signal is present (4-20 mA, 20-4 mA)
cL3
Analog input 3 current loss (current mode)
29
Check analog input 3 (terminal 8) current signal is present (4-20 mA, 20-4 mA)
CL.bit
Trip initiated from the control word (Pr 6.42)
35
Disable the control word by setting Pr 6.43 to 0 or check setting of Pr 6.42
C.OPtn
SMARTCARD trip: Solutions Modules installed are different between source drive and destination drive
Ensure correct Solutions Modules are installed
Ensure Solutions Modules are in the same Solutions Module slot
180
Press the red
C.Prod
SMARTCARD trip: The data blocks on the SMARTCARD are not compatible with this product
Erase all data on the SMARTCARD by setting Pr xx.00 to 9999 and pressing the red
175
Replace SMARTCARD
C.rdo
SMARTCARD trip: SMARTCARD has the Read Only bit set
Enter 9777 in Pr xx.00 to allow SMARTCARD Read / Write access
181
Ensure the drive is not writing to data locations 500 to 999 on the card
C.rtg
SMARTCARD trip: The voltage and/or current rating of the source and destination drives are different
Parameter data or default difference data is being transferred from a SMART card to the drive, but the current and /or voltage ratings
are different between source and destination drives. This trip does not stop the data transfer, but is a warning that the data for the
186
option modules that are different will be set to the default values and not the values from the card.
This trip also applies if a compare is attempted between the data block and the drive.
C.TyP
SMARTCARD trip: SMARTCARD parameter set not compatible with drive
Press the reset button
187
Ensure destination drive type is the same as the source parameter file drive type
dESt
Two or more parameters are writing to the same destination parameter
199
Set Pr xx.00 = 2001 check all visible parameters in the menus for duplication
EEPROM data corrupted - Drive mode becomes open loop and serial comms will timeout with remote keypad on the drive
EEF
RS485 comms port.
31
This trip can only be cleared by loading default parameters and saving parameters
EnC1
Drive encoder trip: Encoder power supply overload
Check encoder power supply wiring and encoder current requirement
189
Maximum current = 200 mA @ 15V, or 300 mA @ 8V and 5V
EnC2
Drive encoder trip: Wire break
Check cable continuity
Check wiring of feedback signals is correct
190
Check encoder power supply is set correctly in Pr 3.36 (Fb06, 0.76)
Replace feedback device
If wire break detection on the main drive encoder input is not required, set Pr 3.40 = 0 to disable the Enc2 trip
EnC3
Drive encoder trip: Overload
191
Overload
158
Electrical
Getting
Basic
Installation
Started
parameters
reset button
reset button
Running