Menu 8: Digital I/O - Emerson Quantum MP User Manual

High performance dc drive size 1 and size 2 45a to 700a, 480v two or four quadrant operation
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
11.8

Menu 8: Digital I/O

Figure 11-9 Menu 8 logic diagram
T24 digital I/O 1
8.29
I/O polarity
select
T25 digital I/O 2
8.29
I/O polarity
select
T26 digital I/O 3
8.29
I/O polarity
select
116
Electrical
Getting
Basic
Running the
Installation
Started
parameters
T24 digital
I/O 1 state
T24 output
8.01
8.30
Open collector
output
T25 digital
I/O 2 state
T25 output
8.02
8.30
Open collector
output
T26 digital
T26 output
I/O 3 state
8.03
8.30
Open collector
output
SMARTCARD
Optimization
Motor
Operation
select
8.31
x(-1)
T24 digital
I/O 1 source/
destination
T24 digital
8.11
I/O 1 invert
x(-1)
select
8.32
x(-1)
6.04
Start/stop
logic select
T25 digital
8.12
I/O 2 invert
x(-1)
select
8.33
x(-1)
6.04
Start/stop
logic select
T26 digital
8.13
I/O 3 invert
x(-1)
www.emersonct.com
Onboard
Advanced
Technical
Diagnostics
PLC
Parameters
Data
At zero
??.??
speed
10.03
??.??
Any bit
parameter
8.21
Any
unprotected
bit parameter
??.??
??.??
Any bit
parameter
??.??
??.??
T25 digital
8.22
I/O 2 source/
destination
Any
unprotected
bit
parameter
??.??
??.??
Any bit
parameter
??.??
??.??
T26 digital
8.23
I/O 3 source/
destination
Any
unprotected
bit
parameter
??.??
??.??
Quantum MP User Guide
UL
Information
Issue: A4

Hide quick links: