Setup - Microscan MS-850 User Manual

Raster
Table of Contents

Advertisement

Setup

Scan Speed
Format: <KEscans per second>
Any number from 35 to 110 (number of scans divided by 10).
Default is 80. (800 scans per second)
Example: To set the scanner to 400 scans per second, send <KE40>.
Analog Gain Adjustment
Format: <KDgain adjustment,AGC samplings>
gain adjustment:
Default is
45
(nominal).
Any number from 10 to 255.
Example: To set the gain threshold to 40 and the AGC status to Leading Edge,
send <KD40,1,0>.
Scanner Type
Format: <KPdensity>
scanner density type:*
0 = Low Density, Medium Density
1 = High Density
* The "default" will depend on the type of scanner.
Caution: Do not change the scanner density type unless instructed to do so by a
Microscan representative.
MS-850 Raster Scanner User's Manual
AGC sampling:
0 = Disabled
1 = Leading Edge
2 =
Continuous

Setup

3-21