Codabar
Format: <Kqstatus,start & stop match status,start & stop output status,large interchar-
acter gap,fixed code length status,code length,check digit type,check digit output>
status:
start & stop match status:
0 = Disabled
0 = Disabled
1 = Enabled
1 = Enabled
large intercharacter gap
:
fixed code length status:
0 = Disabled
0 = Disabled
1 = Enabled
1 = Enabled
check digit type:
2 = NW7
0 = Disabled
3 = Both
1 = Mod 16
Example: To set Fixed Code Length to 9, send <Kq1,,,,1,9> or <Kq1,1,1,0,1,9>.
UCC/EAN-128
Format: <Kt,,,EAN-128 status,output format,application record separator status,appli-
cation record separator character,application brackets,application record padding>
EAN-128 status:
0 = Disabled
1 = Enabled
2 = Required
application record separator
character:
Default is
,
Any ASCII character (except NUL)
MS-850 Raster Scanner User's Manual
Code Type Commands
start & stop output status:
0 = Disabled
1 = Enabled
code length:
Default is
10
Any number from 1 to 64.
check digit output:
0 = Disabled
1 = Enabled
output format:
application record
separator status:
0
Application
0 = Disabled
=
1 = Standard
1 = Enabled
application record
application record
brackets:
padding:
0 = Disabled
0 = Disabled
1 = Enabled
1 = Enabled
3-15