Chapter 3
Serial Configuration
Transition Counter Parameters
Transition Counter
Format: <KHstatus,minimum transitions>
status:
minimum transitions:
0 = Disabled
1 to 255
1 = Enabled
Default is
Example: To change status to enable and set minimum transitions to 24, send
<KH1,24>.
No Barcode Message
Format: <KNstatus,message>
no barcode status:
0 = Disabled
1 = Enabled
Example: To change the message to "NOCODE," send <KN1,NOCODE>.
Bad Barcode Message
Format: <K'status,message>
bad barcode status:
0 = Disabled
1 = Enabled
Example: To change the message to "FAULTY," send <K'1,FAULTY>.
Scanner Setup Status Request
Format: <KU?>
Returns status of each command in the scanner setup group.
3-22
MS-850 Raster Scanner User's Manual
14
message:
Any ASCII string up to 7 characters.
Default is
NO
LABEL.
message:
Default is BADCODE.
Any ASCII string up to 7 characters.