Program Master Labels
After you've set the Size in Data Base (1 to 10 master labels), you can request the
scanner to scan in the next label as the master label for and of your master labels.
You do this by clicking inside the master label box of your choice and clicking the
Program button.
Associated serial commands:
To store next label scanned as master label #1, send:
To store next label scanned as a specific master label, send:
For example,
<G5>
will cause the next label scanned to be entered as master label #5.
Delete Master Labels
You can delete any master label data by directly deleting the text in the appropriate
text box and clicking the Send Text button. The Send Text button will then be grayed
out.
Associated serial commands:
To delete master label #1,
send:<))>
To delete a specific master label, send:
For example, to delete master label #5, Send <M5,>. The blank master label data
field following the comma tells the scanner to delete the indicated master label from
the data base.
MS-850 Raster Scanner User's Manual
<G>
or
<G1>
<G master label #>
or
<M1,>
<Mmaster label #,>
Master Label
4-11
Need help?
Do you have a question about the MS-850 and is the answer not in the manual?