Note: I/O element's "Movement sensor" Averaging constant is interpreted
as Start Move Timeout in seconds (from 1 to 59).
Start Move Timeout – is a time interval required for movement sensor to be
in the moving state, to consider vehicle as moving.

5.15.1 Monitoring

I/O monitoring starts after enabling I/O element and setting up I/O parameters as it
is shown below:

5.15.2 Din3/Ain IO element configuration

Digital input 3 (Din3) and Analog input share the same wire. Depending on the
configuration, it is possible how to use it: as digital input or analog input. In the
configurator it is available as additional parameter to select from:

5.15.3 Event Generating

Events happen when the value of enabled I/O intersects thresholds (enter, exit or
on both) predefined by High and Low level thresholds. Table below defines all available
values of I/O settings.
Setting
Priority
High level
Figure 32. I/O settings
Figure 32. Din3/Ain I/O settings
Value
low, high
maximum threshold
44