Esc P M N1 N2 - Citizen CT-D150 Command Reference Manual

Hide thumbs Also See for CT-D150:
Table of Contents

Advertisement

CT-S280
Support
model
CT-S281
CT-D151/E651

ESC p m n1 n2

[Function]
Generating the specified pulses
[Code]
<1B>H<70>H<m><n1><n2>
[Range]
m=0, 1, 48, 49
0<n1≤n2≤255
[Outline]
[The specification which is common to the model]
• The signals specified by "n1" and "n2" are output to the connector pin specified by "m".
• "m" has the followings.
m
0, 48
1, 49
• The ON time is n1 x2 ms, and OFF time n2 x2 ms.
[Caution]
[The specification which is common to the model]
• When "m" is beyond a definition range, no signal is output, discarding "n1" and "n2".
• The drawer drive duty must be within the following range:
[Sample Program]
LPRINT CHR$(&H1B) + "p"
LPRINT CHR$(0);
LPRINT CHR$(5);
LPRINT CHR$(50);
CT-S300
CT-S2000
CT-S310
CT-S801/851
Connector Pin
Drawer kick-out pin No. 2
Drawer kick-out pin No. 5
ON time
ON time+OFF time
(The OFF time should be 4 times or more longer than the ON time.)
----- Selects pin No. 2.
----- Sets ON time to 10 ms
----- Sets OFF time to 100 ms
- 391 -
CT-S4000
CT-S251
CT-S601/651
CT-P29x series
≤ 0.2
CT-D150/E351
CT-S310II