Fn=11: Function 11 Setting Communication Conditions - Citizen CT-D150 Command Reference Manual

Hide thumbs Also See for CT-D150:
Table of Contents

Advertisement

Support
model
CT-D151/E651

fn=11: Function 11 Setting Communication Conditions

GS ( E pL pH fn a d1...dk
[Code]
<1D>H<28>H<45>H<pL><pH><fn><a><d1>...<dk>
[Range]
3≤(pL+pH×256)≤65535(0≤pL≤255, 0≤pH≤255)
fn=11
1≤a≤4 (Not changed in other than specified range)
48≤d≤57 (Not changed in other than specified range)
1≤k≤6
[Outline]
[The specification which is common to the model]
• Sets the communication conditions of serial interface specified by "a".
• a=1: Setting baud rate
◎---support by
CT-S280/CT-S281/CT-S2000/CT-S4000/CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/
CT-S310II/CT-S251/CT-D150/CT-E351
●---support by
CT-S280/CT-S2000/CT-S4000/CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/CT-S310II/CT-S251/CT-D150/CT-E351/CT-D151/
△---Default :
*
CT-P29x series
does not support
CT-S300/CT-S310/CT-S2000(JPN/EUR)/CT-S4000(JPN/EUR)
▲---Default :
CT-S280/CT-S281/CT-S2000(USA)/CT-S4000(USA)/CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/
CT-P29x
series/CT-S310II/CT-S251/CT-D150/CT-E351/CT-D151/
• a=2: Setting to specified parity
• a=3: Setting to specified flow control
• a=4: Setting to specified data length
• Operates only in printer function setting mode.
• Which of dip SW or memory SW is used at initialization depends on "Selecting communication condition
setting" of dip SW1-1.
CT-S280
CT-S300
CT-S281
CT-S310
Baud Rate
d1
◎1200
49("1")
2400
50("2")
4800
52("4")
△19200
▲9600
57("9")
49("1")
38400
51("3")
●57600
53("5")
●115200
49("1")
115200bps.
d1
Parity Setting
48 (Default)
No parity
49
Odd parity
50
Even parity
d1
Flow Control
48 (Default)
DSR/DTR
49
XON/XOFF
d1
Setting Data Length
55
7-bit length
56 (Default)
8-bit length
CT-S2000
CT-S4000
CT-S801/851
CT-S601/651
d2
d3
50("2")
48("0")
52("4")
48("0")
56("8")
48("0")
54("6")
48("0")
57("9")
50("2")
56("8")
52("4")
55("7")
54("6")
49("1")
53("5")
CT-E651
- 358 -
CT-S251
CT-D150/E351
CT-P29x series
CT-S310II
d4
d5
-
48("0")
48("0")
-
48("0")
-
48("0")
-
48("0")
48("0")
48("0")
48("0")
48("0")
48("0")
50("2")
48("0")
d6
-
-
-
-
-
-
-
48("0")
CT-E651