Fn=4: Function 4 Sending The Set Memory Switch Value - Citizen CT-D150 Command Reference Manual

Hide thumbs Also See for CT-D150:
Table of Contents

Advertisement

Support
model
CT-D151/E651

fn=4: Function 4 Sending the Set Memory Switch Value

GS ( E pL pH fn a
[Code]
<1D>H<28>H<45>H<pL><pH><fn><a>
[Range]
(pL+pH×256)=2
fn=4
CT-S280
a=1, 2, 3
CT-S300
a=1, 2, 3, 4
CT-S281
a=1, 2, 3, 4, 5, 13
CT-S310/CT-S2000/CT-S4000/
a=1, 2, 3, 4, 5
CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/CT-S310II/CT-S251/CT-D150/CT-E351/CT-D1
51/CT-E651
a=1, 2, 3, 4, 5, 6
[Outline]
[The specification which is common to the model]
• Sends the content of MSW set in "a".
• Sends the set value of data in 8-byte data raw in order of bits 8, 7, 6
OFF: 30H ("0")
ON : 31H ("1")
[Caution]
[The specification which depend on the model]
CT-S281/CT-S310/CT-S2000/CT-S4000/
CT-S801/CT-S851/CT-S601/CT-S601/CT-S310II/CT-D150/CT-E351
• MSW7 to MSW10 cannot be sent by this command.
• Transmission is available by <Sending preset customize value>.
CT-S801II/CT-S851II/CT-S601II/CT-S651II/CT-D151/CT-E651
• MSW7 to MSW10,13 cannot be changed by this command. They can be changed by the
setting of customize value.
CT-S251
• MSW7 to MSW10,11,13 cannot be changed by this command. They can be changed by
the setting of customize value.
CT-S280
CT-S300
CT-S281
CT-S310
Hex.
Header
37H
ID
21H
Data
30H or 31H
NULL
00H
CT-S2000
CT-S4000
CT-S801/851
CT-S601/651
CT-P29x series
No. of Data
1
1
8
1
/
CT-P29x series
- 238 -
CT-S251
CT-D150/E351
CT-P29x series
CT-S310II

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents