Panel Switch Commands; Esc C 5 N - Citizen CT-D150 Command Reference Manual

Hide thumbs Also See for CT-D150:
Table of Contents

Advertisement

Support
model
CT-D151/E651

2.2.9 Panel Switch Commands

ESC c 5 n

[Function]
Enabling/disabling the panel switches
[Code]
<1B>H<63>H<35>H<n>
[Range]
0≤n≤255
[Outline]
[The specification which is common to the model]
• Enabling/disabling the FEED switch.
• "n" is valid only for the lowest bit (n0).
• Control by the lowest bit (n0) is shown as follows:
[Caution]
[The specification which is common to the model]
• When the FEED switch is disabled with this command, the paper cannot be fed by operating the
FEED switch.
• While switch operation is waited at the execution of macro, the FEED switch is always enabled regardless of
the setting of this command but no paper feed operation is carried out.
[Default]
n=0
CT-S801(II)/CT-S851(II)
• MSW3-2 OFF: n=0
• MSW3-2 ON : n=1
[Sample Program]
LPRINT CHR$(&H1B);"c5";CHR$(0); ----- When enabling the FEED switch
LPRINT CHR$(&H1B);"c5";CHR$(1); ----- When disabling the FEED switch
CT-S280
CT-S300
CT-S281
CT-S310
n0
0
FEED switch (LF-SW signal) valid
1
FEED switch (LF-SW signal) invalid
CT-S2000
CT-S4000
CT-S801/851
CT-S601/651
Condition
- 148 -
CT-S251
CT-D150/E351
CT-P29x series
CT-S310II

Hide quick links: