High-potential dielectric withstand test
Warning! Dangerous voltage. Follow all safety instructions printed in your appliance tester's user manual
and on your appliance tester.
70. Ensure that the fixture's power cable is not connected to power. Temporarily link the live (brown) and
neutral (blue) conductors in the fixture's power cable together so that there is electrical continuity
between them.
71. Connect one terminal of a PAT (portable appliance tester) device to the combined live and neutral
conductors in the fixture's power cable. Connect the other terminal of the PAT device to the ground
conductor in the fixture's power cable.
72. Make sure that the fixture's main on/off power switch is set to ON.
73. You are about to apply a very dangerous and potentially lethal voltage. Ensure that it is impossible
for exposed conductive components in or on the fixture to come into contact with persons, or any
conductive surface or substance that persons may touch, during this test.
74. Set the maximum current on your PAT device to 20 mA, then use the PAT device to apply 1500 VAC
for a maximum of 1 second to the conductors you have connected it to.
75. If a flashover or arcing occurs, disconnect the PAT device, check all points of the installation, then
repeat the test.
76. Separate the live and neutral conductors again before connecting the fixture to normal AC power.

Lamp adjustment

Before operating an upgraded MAC 2000 Wash XB, carry out lamp adjustment as described in the MAC
2000 Wash XB user manual (P/N 35000219) supplied with the Upgrade Kit.

Product information

For specifications and other information about the product you have upgraded, please refer to the MAC
2000 Wash XB user manual supplied with the MAC 2000 Wash XB Upgrade Kit. This user manual is also
available for download from the Support area of the Martin website at http://www.martin.com
Martin Professional A/S • Olof Palmes Allé 18 • 8200 Aarhus N • Denmark
Tel: +45 8740 0000 • Fax +45 8740 0010 • www.martin.com
MAC 2000 Wash XB Upgrade Kit Installation Guide – Page 34 of 34

Advertisement

Table of Contents
loading

Table of Contents