Service; Replacing The Lamp - Martin Alien 05 User Manual

Hide thumbs Also See for Alien 05:
Table of Contents

Advertisement

S
ERVICE
This section describes service procedures that can be performed by the user. Refer
all service not described here to a qualified Martin technician.
Warning!
Disconnect the fixture from power before removing any cover.
R E P L A C I N G T H E L A M P
The Alien 05 uses the Osram ENL 50W 12V lamp (P/N 97000005). This lamp has
been designed specifically for the Alien 05. Installing any other lamp is likely to
result in a lower light output.
Lamp replacement requires a 3 mm Allen wrench.
Warning!
Allow the fixture sphere to cool for 15 minutes before removing
the lamp cover.
To replace the lamp:
1 Disconnect the fixture from power and allow it to cool.
2 Rotate the sphere to the position shown in the following illustration
3 Remove the lamp cover using a 3 mm Allen wrench.
4 Gently remove the old lamp from its housing and remove it from the socket.
5 Holding the new lamp by its glass base - insert it firmly and squarely into the lamp
socket.

Service

4
13

Advertisement

Table of Contents
loading

Table of Contents