7. Insert the retaining ring, making sure the tab fits in the slot in the
goboholder.
8. Reinstall the retaining spring with the narrow end facing inwards, towards
the retaining ring. Make sure that the outer end of the spring is held
securely in place in the goboholder.
9. Reinstall the goboholder in the gobowheel, sliding the tab on the
goboholder under the clip on the gobowheel and making sure that the
teeth on the goboholder engage in the teeth on the gobo wheel.
10. Reinstall the head cover and be ready for the head to move when you
reapply power.

Lamp replacement

Warning! Wear safety glasses and gloves when handling
lamps.
Allow the fixture to cool for at least 1 hour before handling a
lamp.
To avoid the risk of a discharge lamp exploding in the fixture,
replace the lamp when it reaches its average lifetime (see
'Lamp' on page 41).
Install only lamps that are approved by Martin™ for this fixture
(see 'Lamp' on page 41).
If a lamp breaks, ventilate the room for 30 minutes, put on nitrile
gloves and remove the pieces. Put the pieces in a sealed plastic
bag and take them to your local waste facilities for specialist
recycling. Do not use a vacuum cleaner to clean up pieces of a
broken lamp.
The lamp must be perfectly clean and totally free of oil and grease. Never
touch the lamp with bare hands. If you contaminate the lamp, clean it with an
alcohol wipe and then dry it with a lint-free cloth.