GE D90 Plus Communications Manual page 105

Line distance protection system
Hide thumbs Also See for D90 Plus:
Table of Contents

Advertisement

CHAPTER 2: MODBUS COMMUNICATION
Address
Description
75F4
...Repeated for IEC 61850 GOOSE Analog Input 109
76FB
...Repeated for IEC 61850 GOOSE Analog Input 110
7602
...Repeated for IEC 61850 GOOSE Analog Input 111
7609
...Repeated for IEC 61850 GOOSE Analog Input 112
7610
...Repeated for IEC 61850 GOOSE Analog Input 113
7617
...Repeated for IEC 61850 GOOSE Analog Input 114
761E
...Repeated for IEC 61850 GOOSE Analog Input 115
7625
...Repeated for IEC 61850 GOOSE Analog Input 116
762C
...Repeated for IEC 61850 GOOSE Analog Input 117
7633
...Repeated for IEC 61850 GOOSE Analog Input 118
763A
...Repeated for IEC 61850 GOOSE Analog Input 119
7641
...Repeated for IEC 61850 GOOSE Analog Input 120
7648
...Repeated for IEC 61850 GOOSE Analog Input 121
764F
...Repeated for IEC 61850 GOOSE Analog Input 122
7656
...Repeated for IEC 61850 GOOSE Analog Input 123
765D
...Repeated for IEC 61850 GOOSE Analog Input 124
7664
...Repeated for IEC 61850 GOOSE Analog Input 125
766B
...Repeated for IEC 61850 GOOSE Analog Input 126
7672
...Repeated for IEC 61850 GOOSE Analog Input 127
7679
...Repeated for IEC 61850 GOOSE Analog Input 128
Underfrequency (Read/Write Setting) (6 Modules)
7E00
Underfrequency 1 Function
7E01
Underfrequency 1 Block
7E02
Underfrequency 1 Min Current
7E03
Underfrequency 1 Pickup
7E04
Underfrequency 1 Pickup Delay
7E05
Underfrequency 1 Reset Delay
7E06
Underfrequency 1 Signal Source
7E07
Underfrequency 1 Events
7E09
Underfrequency 1 Reserved (8 items)
7E11
...Repeated for Underfrequency 2
7E22
...Repeated for Underfrequency 3
7E33
...Repeated for Underfrequency 4
7E44
...Repeated for Underfrequency 5
7E55
...Repeated for Underfrequency 6
Neutral Overvoltage (Read/Write Grouped Setting) (3 Modules)
7F00
Neutral Overvoltage 1 Function
7F01
Neutral Overvoltage 1 Signal Source
7F02
Neutral Overvoltage 1 Pickup
7F03
Neutral Overvoltage 1 Pickup Delay
7F04
Neutral Overvoltage 1 Reset Delay
7F05
Neutral Overvoltage 1 Block
7F07
Neutral Overvoltage 1 Events
7F08
Neutral Overvoltage 1 Curves
7F09
Neutral Overvoltage 1 Reserved (7 items)
7F10
...Repeated for Neutral Overvoltage 2
PLUS
D90
LINE DISTANCE PROTECTION SYSTEM – COMMUNICATIONS GUIDE
Range
Units
0 to 1
---
0 to 65535
---
0.1 to 1.25
pu
20 to 65
Hz
0 to 65.535
s
0 to 65.535
s
0 to 5
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 5
---
0 to 1.25
pu
0 to 600
s
0 to 600
s
0 to 65535
---
0 to 1
---
0 to 3
---
0 to 65535
---
MODBUS MEMORY MAP
Step
Format
Default
1
F102
0 (Disabled)
1
F300
0
0.01
F001
10
0.01
F001
5950
0.001
F001
2000
0.001
F001
2000
1
F167
0 (SRC 1)
1
F102
0 (Disabled)
1
F001
0
1
F102
0 (Disabled)
1
F167
0 (SRC 1)
0.001
F001
300
0.01
F001
100
0.01
F001
100
1
F300
0
1
F102
0 (Disabled)
1
F096
0 (Definite
Time)
1
F001
0
101

Advertisement

Table of Contents
loading

Table of Contents