GE D90 Plus Communications Manual page 14

Line distance protection system
Hide thumbs Also See for D90 Plus:
Table of Contents

Advertisement

MODBUS MEMORY MAP
Address
Description
Product Information (Read Only)
0000
UR Product Type
0002
Product Version
Product Information (Read Only - Written by Factory)
0010
Serial Number
0020
Manufacturing Date
0022
Modification Number
Product Information (Read Only Non-Volatile)
0023
Operating Time
Product Information (Read Only - Written by Factory)
0040
Order Code
0090
Ethernet MAC Address
0093
Reserved (13 items)
Communications Actual Values (Read Only)
0128
Modbus Available TCP/IP Connections
0129
MMS Available TCP/IP Connections
012A
PMU Available TCP/IP Connections
012B
IEC Available TCP/IP Connections
012C
DNP Available TCP/IP Connections
0130
Port 1 Ethernet Actual Mode
0131
Port 1 Ethernet Duplex
0132
Port 1 Ethernet Speed
0133
Port 1 Ethernet Link Status
0134
Port 2 Ethernet Actual Mode
0135
Port 2 Ethernet Duplex
0136
Port 2 Ethernet Speed
0137
Port 2 Ethernet Link Status
0138
Port 3 Ethernet Actual Mode
0139
Port 3 Ethernet Duplex
013A
Port 3 Ethernet Speed
013B
Port 3 Ethernet Link Status
013C
Configure IP Network Status
013D
Active Port 1 IP Address
013F
Active Port 1 IP Subnet Mask
0141
Active Port 1 Gateway IP Address
0143
Active Port 2 IP Address
0145
Active Port 2 IP Subnet Mask
0147
Active Port 2 Gateway IP Address
0149
Active Port 3 IP Address
014B
Active Port 3 IP Subnet Mask
014D
Active Port 3 Gateway IP Address
10
Table 10: Modbus memory map
Range
Units
0 to 65535
---
0 to 655.35
---
---
---
0 to 4294967295
---
0 to 65535
---
0 to 4294967295
---
---
---
---
---
---
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 2
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 2
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 2
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 19
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
PLUS
D90
LINE DISTANCE PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 2: MODBUS COMMUNICATION
Step
Format
Default
1
F001
0
0.01
F001
110
---
F203
"0"
1
F050
0
1
F001
0
1
F050
0
---
F204
"Order Code
x"
---
F072
0
---
F001
0
---
F001
0
---
F001
0
---
F001
0
---
F001
0
---
F001
0
1
F192
0 (10/100
BASE-TX)
1
F171
0 (Half
Duplex)
1
F170
0 (10 Mps)
1
F155
0 (Offline)
1
F192
0 (10/100
BASE-TX)
1
F171
0 (Half
Duplex)
1
F170
0 (10 Mps)
1
F155
0 (Offline)
1
F192
0 (10/100
BASE-TX)
1
F171
0 (Half
Duplex)
1
F170
0 (10 Mps)
1
F155
0 (Offline)
1
F173
0 (OK)
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0

Advertisement

Table of Contents
loading

Table of Contents