Site Environmental Requirements; Physical Characteristics - Cisco RFGW-10 Hardware Installation Manual

Rf gateway 10
Hide thumbs Also See for RFGW-10:
Table of Contents

Advertisement

Site Planning
The Cisco RFGW-10 UEQAM are designed to meet the industry EMC, safety, and environmental
standards described in the
document.

Site Environmental Requirements

Environmental monitoring in the Cisco RFGW-10 UEQAM protects the system and components from
damage caused by excessive voltage and temperature conditions. To ensure normal operation and avoid
unnecessary maintenance, plan and prepare your site configuration before installation. After installation,
make sure the site maintains the environmental characteristics as shown in
Table 2-2
Cisco RFGW-10 UEQAM Environmental Tolerances
Environmental Characteristic
Steady State Operating
Storage
Humidity operating (noncondensing)
Humidity nonoperating (noncondensing)
Altitude operating: over allowable temperature range 32°F to
122°F (0 to 50°C)
Altitude operating: over allowable temperature range 32°F to
104°F (0 to 40°C)
Altitude, nonoperating: over allowable temperature range

Physical Characteristics

Be familiar with the physical characteristics of the Cisco RFGW-10 UEQAM to assist you in placing the
system in the proper location.
Table 2-3
Table 2-3
Physical Characteristics of Cisco RFGW-10 UEQAM
Characteristic
Height
Width
Depth
Weight of fully configured chassis
Cisco RF Gateway 10 Hardware Installation Guide
2-8
Regulatory Safety and Compliance Information for the Cisco RF Gateway 10
shows the weight and dimensions of the Cisco RFGW-10 UEQAM.
Chapter 2
Minimum
32°F (0°C)
–4°F (–20°C)
5%
5%
–200 feet
–200 feet
–200 feet
Cisco RFGW-10 UEQAM
22.75 in. (57.785 cm)
17.48 in. (44.4 cm) with rack-mounts
Overall depth including card handles, UCH2 cable holders,
power supply handles: 24.93 in. (63.32 cm)
Depth from the front rack-mount bracket including card
handles, UCH2 cable holders, power supply handles: 24.13
in. (61.29 cm)
Depth from the front rack-mount bracket including rear RF
cable-management bracket: 26 in. (66 cm)
275 lbs (125 kg) (with 10 DS-48 line cards and two DC
PEMs)
Preparing Your Site for Installation
Table
2-2.
Maximum
104°F (40°C) at 10,000 feet
158°F (70°C)
90%
95%
6,000 feet
10,000 feet
30,000 feet
OL-16264-04