1 Outline
1.5.2 Connecting to SGDV-A05 SERVOPACK
1.5.2 Connecting to SGDV-A05 SERVOPACK
(1) Using a Three-phase, 200-V Power Supply
Power supply
Three-phase 200 VAC
R S T
Molded-case
circuit breaker
(MCCB)
Protects the power
line by shutting the
circuit OFF when
overcurrent is
detected.
Noise filter
Eliminates
external noise from
the power line.
Regenerative
resistor*
Servomotor main
circuit cable
Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.6 Connecting Regenerative Resis-
tors.
1-16
SGDV-
A05
SERVOPACK
Magnetic
contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
Connection cable for
serial converter unit
Serial converter unit
Connection cable
for linear scale
Linear scale
(not included)
www.dadehpardazan.ir 88594014-15
Connection cable
for digital operator
Connection cable
for personal computer
I/O signal cable
When not using the safety function,
use the SERVOPACK with the safety
function's jumper connector
(JZSP-CVH05-E, provided as an
accessory) inserted.
When using the safety function,
insert a connection cable specifically
for the safety function.
Servomotor with core
47
Digital
operator
Personal
computer
Host controller
Safety function
devices
Connection cable
for hall sensor