1 Outline
1.1
-V Series SERVOPACKs
The -V Series SERVOPACKs are designed for applications that require frequent high-speed, high-pre-
cision positioning. The SERVOPACK makes the most of machine performance in the shortest time possi-
ble, thus contributing to improving productivity.
1.2

Part Names

This section describes the part names of SGDV SERVOPACK for analog voltage and pulse train reference.
Serial number
Panel display
Used to display SERVOPACK
status, alarm numbers, and other
values when parameters are input.
Refer to 2.1 Overview.
Front cover
Nameplate (Found on side of SERVOPACK.)
Indicates the SERVOPACK model and ratings.
Charge indicator
Lights when the main circuit power supply is ON
and stays lit as long as the internal capacitor
remains charged. Therefore, do not touch the
SERVOPACK even after the power supply is
turned OFF if the indicator is lit.
It may result in electric shock.
Main circuit power supply terminals
Used for main circuit power supply input.
Refer to 3.1 Main Circuit Wiring.
Control power supply terminals
Used for control power supply input.
Refer to 3.1 Main Circuit Wiring.
Regenerative resistor connecting terminals
Connects external regenerative resistors.
Refer to 3.6 Connecting Regenerative Resistors.
DC reactor terminals for harmonic suppression
Connects DC reactor for harmonic suppression.
Refer to 3.7.3 Connecting a Reactor for
Harmonic Suppression.
Servomotor terminals
Connects the main circuit cable for servomotor.
Refer to 3.1 Main Circuit Wiring.
Ground terminal
Be sure to connect to protect against electric shock.
Refer to 3.1 Main Circuit Wiring.
1-2
With front cover open
Panel operator
www.dadehpardazan.ir 88594014-15
CN5 Analog monitor connector
Used to monitor motor speed, force
reference, and other values through
a special cable (option).
Refer to 6.1.3 Monitoring Operation during Adjustment.
Panel operator keys
Used to set parameters.
Refer to 2.1 Overview.
Input voltage
SERVOPACK model
Refer to 1.6 SERVOPACK Model Designation.
CN3 Connector for digital operator
Connects a digital operator (option, JUSP-OP05A-
1-E) or a personal computer (RS422).
CN3
Refer to
-V Series Product Catalog (No.: KAEP
S800000 42) and
ation of Digital Operator (No.: SIEP S800000 55).
CN7
CN7 Connector for personal computer (USB connector)
Communicates with a personal computer.
Use the connection cable (JZSP-CVS06-02-E).
CN1 I/O signal connector
CN1
Used for reference input signals and sequence I/O signals.
Refer to 3.2 I/O Signal Connections.
CN8 Connector for safety function devices
CN8
Connects a safety function device.
Note: When not using the safety function, use the
SERVOPACK with the safety function's jumper
connector (JZSP-CVH05-E, provided as an ac-
cessory) inserted.
CN2
For the connecting method, refer to 3.2.2 Safety
Function Signal (CN8) Names and Functions.
For details on how to use the safety function, re-
fer to 5.11 Safety Function.
CN2 Linear scale connector
Connects a serial convertor unit or linear scale.
Refer to 3.5 Linear Scale Connection.
47
-V Series User's Manual, Oper-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgtSglgwSglfwSgltwSglc

Table of Contents