Force Reference Filter - YASKAWA SGDV SERVOPACK User Manual

E-v series, linear servomotors
Hide thumbs Also See for SGDV SERVOPACK:
Table of Contents

Advertisement

6.9.6 Force Reference Filter

As shown in the following diagram, the force reference filter contains first order lag filter and notch filters
arrayed in series, and each filter operates independently. The notch filters can be enabled and disabled with the
Pn408.
Force
Force
reference
Reference
before
Filter
(Pn401)
filtering
First order lag filter
* The 2nd force reference filter is enabled when Pn40F is set to a value less than
5000 and disabled when Pn40F is set to 5000 (factory setting).
(1) Force Reference Filter
If you suspect that machine vibration is being caused by the servo drive, try adjusting the filter time constants
with Pn401. This may stop the vibration. The lower the value, the better the response will be, but there may be
a limit that depends on the machine conditions.
Force Reference Filter Time Constant
Pn401
Setting Range
Force
Reference Filter Setting Guide
Use the speed loop gain (Pn100 [Hz]) and the force filter time constant (Pn401 [ms]) to set the force reference
filter.
Adjusted value for stable control: Pn401 [ms]  1000/ (2Pn100 [Hz]  4)
Critical gains: Pn401 [ms] < 1000/ (2Pn100 [Hz]  1)
2nd Step 2nd Force Reference Filter
Frequency
Pn40F
Setting Range
2nd Step 2nd Force Reference Filter Q
Value
Pn410
Setting Range
The filter is disabled if 5000 is set.
*
2nd Force
Reference
Filter
(Pn40F,
Pn410)
Second order lag filter
Setting Unit
0 to 65535
0.01 ms
Setting Unit
100 to 5000
1 Hz
Setting Unit
50 to 100
0.01
www.dadehpardazan.ir 88594014-15
6.9 Compatible Adjustment Function
Force Related
Function Switch
Pn408
2nd
1st Notch
Notch
Filter
Filter
(Pn409,
(Pn40C,
Pn40A,
Pn40D, and
and Pn40B)
Pn40E)
Notch filter
Notch filter
Position
Force
Speed
Factory Setting
When Enabled
100
Immediately
Position
Force
Speed
Factory Setting
When Enabled
5000*
Immediately
Position
Speed
Force
Factory Setting
When Enabled
50
Immediately
Linear
Force
reference
after
filtering
Classification
Tuning
Classification
Tuning
6
Classification
Tuning
6-69