SYSTEM ADMINISTRATOR'S GUIDE
B7.3 PBX Interface Parameters
Three separate parameters are used to program the VPS for optimal signalling and performance
with the PBX.
To access the proper menu for PBX Interface Parameters, follow the menu path as
shown:
System Administration Top Menu-1-6-3
Dialing Parameters
These parameters specify how the VPS will initiate and control call transfers, setup outgoing
calls, and control message waiting lamps on extensions. The procedure for verifying the correct
code sequences for non-Panasonic KX-T series telephone systems is to manually execute the
sequences from a single line telephone (SLT) with the PBX.
To access the proper menu for Dialing Parameters, follow the menu path as shown:
System Administration Top Menu-1-6-3-1
Parameter
PBX Type
282
Value Range
(Default)
1. Other Manufacturers
2. KX-T Series
1. T308
2. T616
3. T1232/TA series
4. T96
5. T336
6. TD816
7. TD1232
8. TD500
9. Reserved
(TD1232)
Table 71
Description/Function
Specifies the type of PBX connected to the VPS. In
the case of a Panasonic KX-T series telephone
system, the model number should also be specified.
Note: The Dialing Parameters are set automatically to
each PBX default value after selecting the PBX type.
Installation Manual