SYSTEM ADMINISTRATOR'S GUIDE
N/A Not available
— Not needed
Parameter
Integration
Mode
To program the following 10 Parameters in the next table, use the Special Commands and Dial
Codes listed below. You can set up to 12 digits for each parameter.
D: Disconnecting
F: Hook Flash
R: Ringback Tone Detection
S: Silence Detection
T: Dial Tone Detection
W: Wait for 1 s
X: Extension dialling
A: Answer
1-9, 0, , #: Dial Codes
284
Value Range
(Default)
1. None
Specifies the method of integrating the VPS with the
2. Inband
PBX.
3. DPT
1. None—Both PBX and VPS work independently,
(DPT)
2. Inband—The PBX sends touchtone codes to the VPS
3. DPT—The VPS communicates with the PBX via the
Table 73
Description/Function
without accessing information concerning the status
of the other.
to indicate the state of the call (busy, answered,
disconnect, etc.). Inband Integration improves the
VPS performance because call state recognition is
faster than with standard call progress tone detection.
The PBX code for each call state must be set in the
Inband Signaling Parameters. If PBX type is set to a
KX-T series telephone system, the Inband Signaling
Parameters will automatically default to the proper
codes. This is available with any of the following
Panasonic KX-T series telephone systems: T1232,
TA series, T96, T336, TD816, TD1232, and TD500.
DPT interface. This is available with any of the
following Panasonic KX-TD series telephone
systems: TD816, TD1232, and TD500.