GAn : n referes to command GA.
RFnnnn.nnnn (MHz)
MDn : n refers to command MD.
ATn : n refers to command AT.
AMn : n refers to command AM.
TMxx... : xx... message of maximum 12 letters. It is possible to omit it.
Command only valid for setup.
NP NTSC/PAL select
Setup: NPmn<CR>
Acquisition: NP<CR>
OF Offset
Setup: OFn<CR>
Acquisition: OF<CR>
OL Offset frequency
Setup: OLxmmm.nnnn<CR>
Acquisition: OL<CR>
OM Operation mode
Setup: OMn<CR>
Acquisition: OM<CR>
PD Pass frequency delete
Setup: PDmmnn<CR> mm = 01 ~ 40 (search bank)
PM Spectrum plot image
Setup: PMn<CR>
Acquisition: PM<CR>
PP Priority monitor setting
Setup: PPmnn<CR> m = 0 ~ 9 (memory bank)
nn = 00 ~ 99 (channel number)
It is possible to omit it, in which case it is specified by GA0.
It is possible to omit it, in which case it is specified by AT0.
It is possible to omit it, in which case it is specified by AM1.
m: spectrum screen output
M=0 (NTSC), m=1(PAL)
n : Video decode
n = 0 (NTSC)
n = 1 (PAL)
n = 2 (AUTO) Default : 02
Response value : NPmn
n = 0 (offset reception off)
n = 1 (offset reception on) Default : 0
Response value : OFn
x: + or –
The offset direction is therefore indicated.
mmm.nnnn = 0.0001 (100Hz) ~ 999.9999 (MHz)
Default : 0
Response value : Olxmmm.nnnn
n = 0 (spectrum analyzer mode)
n = 1 (step resolution mode)
n = 2 (channel scope mode) Default : 0
Response value : OMn
nn = 00 ~ 49 (channel)
Both bank and channel numbers must be in two
digit format.
Command valid only for setup.
n = 0 (paint)
n = 1 (outline) Default : 0
Response value : PMn