If the video signal frequency is below 1,000 MHz, then the AM video mode will be
automatically selected.
If the video signal frequency is above 1,000 MHz, then the FM video mode will be
automatically selected.
To activate the video function, perform the following steps:
1.
In the VFO mode or the spectrum analyzer mode, set the voice frequency of the video
signal.
2.
Press the FUNC key.
3.
A soft key menu will appear on the bottom of the LCD.
4.
Press the Video soft key.
To return to the normal spectrum analyzer screen, push any soft key.
[Note] Some video transmitters utilizes the reversed frequency shift modulation in order to
set signals scrambled. In this case, the video signal can be descrambled by
performing following steps:
1. In the configuration menu (see Chapter 7, Configuration), select the V.FREQ DIR.
2. Select NORMAL or REVERSE to descramble video signal.
7 Configuration
In this chapter, we learn how to set fundamental operating parameters of the SR2000A.
To access the SR2000A's configuration menu, press the FUNC key, then press the
9 key.
[WSP 20M]
[WSP 40M]
[Video]