AOR SR2000A Instruction Manual page 49

Frequency monitor
Hide thumbs Also See for SR2000A:
Table of Contents

Advertisement

Response to the read command:
Following the output of the parameter, the correct response should read:
<SP><CR><LF> (0x20 0x0d 0x0a)
Numerical parameter auto-correct
The SR2000A correct the numerical command parameter to the digit format applying to
the given parameter. In the following example, the DB command has to be followed by
a 3 digit number.
[Example]
The SR2000A will add one or two "0" in order to achieve three digits.
DB3<CR> ----- processed as DB003<CR>
DB03<CR> ---- processed as DB003<CR>
However be aware that for some commands like Memory channel or Search bank, if
You input MQ33 for MQ303 (bank 3, channel 3), the SR2000A would mistakenly correct
your entry to MQ033 which means bank 0, channel 33.
Format of the data output to PC at search and scan:
FFT search
DL-mm RFnn...
Mm: dB level, nn... : frequency [Hz]
Before "mm" be sure to add "-" (minus)
Normal search and scan
ATn AMn SQn LCxxx RFmmmmnnnnn
Refer to AT, AM, SQ, LC, RF commnds for detail
48

Advertisement

Table of Contents
loading

Related Products for AOR SR2000A

Table of Contents