CHARGING SYSTEM INSPECTION

CURRENT LEAKAGE TEST

Turn the ignition switch
ative
Connect the ammeter
cable and the ammeter
minal.
With the ignition switch OFF, check for current leak-
age.
NOTE:
SPECIFIED CURRENT LEAKAGE: 0.1 mA max.
If current leakage exceeds the specified value, a
shorted circuit is likely.
Locate the short by disconnecting connections one
by one and measuring the current.

CHARGING VOLTAGE INSPECTION

If the engine must be running t o do some work,
make sure the area is well ventilated. Never run the
engine in an enclosed area. The exhaust contains
poisonous carbon monoxide gas that may cause loss
of consciousness and may lead t o death. Run the
engine in an open area or with an exhaust evacua-
tion system in an enclosed area.
NOTE:
Be sure that the battery is in good condition before
Start the engine and warm it up to the operating tern-
perature; stop the engine.
Connect the multimeter between the positive and
negative terminals of the battery.
' -
CAUTION
OFF,
cable from the battery.
probe to the negative
probe to the battery
When measuring current using a tester, set it to a
high range, and then bring the range down to an
appropriate level. Current flow higher than the
range selected may blow out the fuse in the tester.
While measuring current, do not turn the ignition
switch ON. A sudden surge of current may blow
out the fuse in the tester.
To prevent short, make absolutely certain which
are the positive and negative terminals or cable.
Do
not disconnect the battery or any cable in the
charging system without first switching off the
ignition switch. Failure to follow this precaution
can damaae the tester or electrical comnonenh.