Stator Removal/Installation - Honda TRX400EX FOURTRAX 1999 Service Manual

Table of Contents

Advertisement

Remove the nut, seven bolts and the left crankcase
cover.
Remove the gasket and dowel pins.
Remove the starter reduction gear shaft and gear.

STATOR REMOVAL/INSTALLATION

Remove the bolt and wire clamp.
Remove the two ignition pulse generator bolts and
wire clamp.
Remove the three stator bolts.
Remove the wire grommet and statorlignition pulse
generator assembly from the left crankcase cover.
Install the statorlignition pulse generator assembly
onto the left crankcase cover.
Apply sealant to the wire grommet seating surface
and install it into the cover groove properly.
Install the stator bolts and tighten them securely.
Apply locking agent to the ignition pulse generator
bolt threads.
Install the wire clamp onto the ignition pulse genera-
tor
Apply locking agent to the wire clamp bolt threads.
Install the wire clamp and tighten the bolt securely.
.-
and tighten the two bolts securely.
,GROMMET
C
.
BOLTS
GENERATOR
10-3