Clock Plls - Texas Instruments TMS320C6748 Manual

Fixed- and floating-point dsp
Hide thumbs Also See for TMS320C6748:
Table of Contents

Advertisement

www.ti.com
Table 6-3. OSCIN Timing Requirements for an Externally Driven Clock
f
OSCIN frequency range
OSCIN
t
Cycle time, external clock driven on OSCIN
c(OSCIN)
t
Pulse width high, external clock on OSCIN
w(OSCINH)
t
Pulse width low, external clock on OSCIN
w(OSCINL)
t
Transition time, OSCIN
t(OSCIN)
t
Period jitter, OSCIN
j(OSCIN)
(1) Whichever is smaller. P = the period of the applied signal. Maintaining transition times as fast as possible is recommended to improve
noise immunity on input signals.
6.6

Clock PLLs

The device has two PLL controllers that provide clocks to different parts of the system. PLL0 provides
clocks (though various dividers) to most of the components of the device. PLL1 provides clocks to the
DDR2/mDDR Controller and provides an alternate clock source for the ASYNC3 clock domain. This allows
the peripherals on the ASYNC3 clock domain to be immune to frequency scaling operation on PLL0.
The PLL controller provides the following:
Glitch-Free Transitions (on changing clock settings)
Domain Clocks Alignment
Clock Gating
PLL power down
The various clock outputs given by the controller are as follows:
Domain Clocks: SYSCLK [1:n]
Auxiliary Clock from reference clock source: AUXCLK
Various dividers that can be used are as follows:
Post-PLL Divider: POSTDIV
SYSCLK Divider: D1, ¼, Dn
Various other controls supported are as follows:
PLL Multiplier Control: PLLM
Software programmable PLL Bypass: PLLEN
Copyright © 2009–2017, Texas Instruments Incorporated
OSCIN
OSCOUT
NC
OSCV
SS
Figure 6-7. External 1.2V Clock Source
PARAMETER
Submit Documentation Feedback
Product Folder Links:
SPRS590G – JUNE 2009 – REVISED JANUARY 2017
Clock
Input
to PLL
MIN
12
20
0.4 t
c(OSCIN)
0.4 t
c(OSCIN)
Peripheral Information and Electrical Specifications
TMS320C6748
TMS320C6748
MAX
UNIT
50
MHz
ns
ns
ns
(1)
0.25P or 10
ns
0.02P
ns
87

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omap-l138 c6000