6 Configurations

All Jumper selections should be made prior to applying power to the EVM. User can configure this EVM per
following configurations.

6.1 Mode and Soft-Start Time Selection

The operation mode and soft-start time can be set by J4.
6.1.1 Default Setting: Skip Mode, 6-ms SS
MODE RESISTANCES
10.0 kΩ
20.0 kΩ
39.0 kΩ
82.0 kΩ
160 kΩ
Open

6.2 Overcurrent Protection (OCP) Selection

The OCP threshold can be set by J6.
6.2.1 Default Setting: 9-A OCP
OCP SETTING CAPACITANCE

6.3 Enable Selection

The converter can be enabled and disabled by J1.
6.3.1 Default Setting: Short to Disable the Converter

6.4 Switching Frequency Selection or External Clock Input for Synchronization

The switching frequency can be set by J3. If the external clock is used for synchronization, the external clock
should be connected to TP5 (SYNC) and TP7 (GND).
6.4.1 Default setting: 600 kHz
SWITCHING FREQUENCY SETTING RESISTANCES
80.6 kΩ
45.3 kΩ
SLUU819A – DECEMBER 2011 – REVISED DECEMBER 2021
Submit Document Feedback
All manuals and user guides at all-guidesbox.com

Table 6-1. MODE Selection

OPERATION MODE

Table 6-2. OCP Selection

10 nF
2.2 nF
Open

Table 6-3. Switching Frequency Selection

Copyright © 2021 Texas Instruments Incorporated
FCCM
FCCM
FCCM
Skip
Skip
Skip
OVERCURRENT LIMIT
SWITCHING FREQUENCY
TPS53313 Step-Down Converter Evaluation Module User's Guide
Configurations
SOFT-START TIME
6 ms
3 ms
1 ms
6 ms
3 ms
1 ms
9 A
4.5 A
6 A
600 kHz
1.00 MHz