52.5

Configuring Basic Test Call

The Basic Test Call feature tests incoming Gateway calls from a remote SIP endpoint to a
simulated test endpoint on the device. The only required configuration is to assign a prefix
number (test call ID) to the simulated endpoint. All incoming calls with this called
(destination) prefix number is identified as a test call and sent to the simulated endpoint.
The figure below displays a basic test call example.
To configure basic call testing:
1.
Open the Test Call Settings page (Configuration tab > System menu > Test Call >
Test Call Settings).
2.
In the 'Test Call ID' field, enter a prefix for the simulated endpoint.
3.
Click Submit.
Notes:
The Basic Test Call feature tests incoming calls only and is initiated only upon
receipt of incoming calls with the configured prefix.
For a full description of this parameter, see ''SIP Test Call Parameters'' on page
716.
This call test is done on all SIP interfaces.
This call test is applicable only to the Gateway application.
User's Manual
Figure 52-4: Incoming Test Call Example
Figure 52-5: Test Call Settings Page