To configure and activate debug recording:
1.
Open the Logging Settings page (Configuration tab > System menu > Logging >
Logging Settings).
2.
Configure the debug capturing server using the 'Debug Recording Destination IP' and
'Debug Recording Destination Port' parameters.
3.
From the 'Debug Recording Status' drop-down list, select Start to start the debug
recording or Stop to end the recording.
4.
Click Submit.
For a detailed description of these parameters, see ''Syslog, CDR and Debug Parameters''
on page 717.
49.5

Filtering Syslog Messages and Debug Recordings

The device can filter Syslog messages and debug recording (DR) packets, which are sent
to a Syslog server and packet capturing application (such as Wireshark), respectively.
Filtering can be useful to reduce CPU consumption and minimize negative impact on VoIP
performance.
You can configure up to 30 filtering rules, each based on a selected filtering criteria (e.g.,
an IP Group). Each filtering criteria can be configured with a range. For example, you can
filter Syslog messages for IP Groups 1 through 4. For each filter criteria, you can enable or
disable Syslog messages and debug recording.
Debug recording can also be filtered using various filtering criteria such as SIP signaling or
signaling and media.
The following procedure describes how to configure Logging Filter rules in the Web
interface. You can also configure Logging Filter rules using the table ini file parameter,
LoggingFilters or the CLI command configure system > logging > logging-filters.
To configure a logging filtering rule:
1.
Open the Logging Filters Table page (Configuration tab > System menu > Logging
> Logging Filters Table).
2.
Click Add; the following dialog box appears:
Figure 49-4: Logging Filters Table - Add Record Dialog Box
3.
Configure a logging filter according to the parameters described in the table below.
4.
Click Submit, and then save ("burn") your settings to flash memory.